نصائح القياس الرقمي المتعدد

Jan 16, 2022

1. قياس مكبرات الصوت وسماعات الأذن والميكروفونات الديناميكية:

Use the R1Ω gear, connect any test pen to one end, and the other test pen touches the other end. Normally, a crisp and loud "click" sound will be emitted. If there is no sound, the coil is broken. If the sound is small and sharp, there is a problem of rubbing the coil and it cannot be used.

2 قياس السعة:

استخدم الكهرباء للحظر ، وحدد النطاق المناسب وفقًا لقدرة السعة ، وانتبه إلى القطب الموجب للمكثف لرصاص الاختبار الأسود للمكثف الإلكتروليتي أثناء القياس.

①. Estimate the size of the microwave-class capacitor capacity: it can be determined by experience or by referring to the standard capacitor of the same capacity, according to the maximum amplitude of the pointer swing. The reference capacitors do not have to have the same withstand voltage value, as long as the capacity is the same. For example, a 100μF/250V capacitor can be estimated by a 100μF/25V capacitor as a reference. As long as the maximum amplitude of their pointer swings is the same, it can be concluded that the capacity is the same.

②. Estimate the capacitance of the pico-farad level capacitor: use R10kΩ block, but only the capacitance above 1000pF can be measured. For 1000pF or slightly larger capacitors, as long as the needle swings slightly, it can be considered that the capacity is sufficient.

3. Measure whether the capacitor is leaking: For capacitors above 1,000 microfarads, you can use the R10Ω block to quickly charge it first, and initially estimate the capacitance capacity, then change to the R1kΩ block and continue to measure for a while, when the pointer does not Should return, but should stop at or very close to ∞, otherwise there will be leakage. For some timing or oscillating capacitors below tens of microfarads (such as the oscillating capacitors of color TV switching power supplies), their leakage characteristics are very high, and they cannot be used as long as there is a slight leakage. Then use the R10kΩ block to continue the measurement, and the needle should stop at ∞ instead of returning.


GVDA Digital Multimter GD118B Green color : 

Pls Clink Below Photo and Read more details about this GVDA Digital Multimter GD118B اللون الأخضر:


6